Nouvo Konsepsyon Aparèy Pwoteksyon Surge 2P 600 800VDC
|
Modèl |
FSP-D40 |
|
||
|
UC (V DC) |
600/800V |
|
||
|
Max Kouran Egzeyat Sistèm (8/20 μs) [Imax] |
40kA |
|
||
|
Nivo Pwoteksyon Voltage [UP] |
Mwens pase oswa egal a 2.5kV |
|
||
|
Entegre Fuse Kase Kapasite / Entewonp Rating |
40kA/600Vdc |
|
||
|
Teknoloji |
Kout-Circuit Interruption (SCI) Pwoteksyon Overcurrent |
|
||
|
Ranje Tanperati Fonksyònman [TU] |
-40 degre a plis 80 degre |
|
||
|
Nominal Discharge Current (8/20 μs) [(DC+/DC-) -->PE] [n] |
20kA |
|
||
|
Tan repons [tA] |
<25ns |
|||
|
Endikasyon Eta Fonksyònman/Fòt |
Vèt (bon)/Wouj (ranplase) |
|
|
|
|
Evalyasyon kondiktè ak zòn transvèsal |
Min |
|||
|
Montaj |
Max |
60/75 degre 1.5mm2/14AWG Solid/Fleksib |
|
|
|
35mm DIN Rail pa EN 60715 |
60/75 degre 35mm/2AWG bloke/25mm2/4AWG fleksib |
|||
|
Materyèl patiraj |
UL 94V0 Thermoplastik |
|
|
|
|
Degre Pwoteksyon |
IP20 |
|||
|
Kapasite |
3 Modil, DIN 43880 |
|
|
|
|
Enfòmasyon sou Estanda |
IEC 61643-31 Kalite 2, IEC 61643-1 Klas II |
|||
|
Garanti pwodwi |
De ane** |
|
|
|
|
|
|
|
|
|
1) Seleksyon nivo pwoteksyon vòltaj (UP)
Valè a nan UP pa ta dwe depase valè nominal nan vòltaj la kenbe tèt ak enpilsyon nan ekipman an pwoteje, ak UP mande pou izolasyon nan SPD a ak ekipman ki pwoteje yo ta dwe byen matche.
Nan ekipman pou pouvwa ba-vòltaj la ak sistèm distribisyon, ekipman an ta dwe gen yon kapasite sèten yo kenbe tèt ak vag, se sa ki, kapasite nan kenbe tèt ak ovèvoltaj enpilsyon. Lè enpilsyon survoltaj kenbe tèt ak vòltaj nan divès ekipman nan 220/380V twa-faz sistèm pa ka jwenn, li ka chwazi dapre endèks la bay nan IEC 60664-1 ak GB 50057-1994 (2000 edisyon).
2) Seleksyon aktyèl egzeyat nominal In (kapasite aktyèl enpak)
Kouran pik nan vag aktyèl 8/20 μs ki koule nan SPD la. Li se itilize pou klas II tès klasifikasyon pou SPD, epi tou yo itilize pou pretreatment nan klas I ak klas II tès klasifikasyon pou SPD.
An reyalite, Nan se pik maksimòm valè aktyèl la inrush ke SPD a ka pase kantite fwa espesifye (jeneralman 20 fwa) ak fòm vag espesifye (8/20 μs) san domaj sibstansyèl.
3) Seleksyon maksimòm egzeyat aktyèl la Imax (limit enpak aktyèl kapasite)
The peak current flowing through SPD, 8/20 μs current wave, used for class II classification test. There are many similarities between Imax and In. They both use the peak current of 8/20 μs current wave to do Class II classification test on SPD. The difference is also obvious. Imax only does one impact test on SPD, and SPD does not undergo substantial damage after the test; while In can do 20 such tests, SPD cannot have substantial damage after the test. Therefore, Imax is the current limit value of the impact, so the maximum discharge current is also called the limit impact current capacity. Obviously, Imax>Nan.
Anbalaj & Shipping
Pake Surge Arrester:
Anbalaj katon ekspòtasyon estanda:
2P DC SPD 72pcs/ctn
3P DC SPD 48pcs/ctn
Carton Size 48 * 29.5 * 15.2CM3
GW/NW: 20.7/20.1kgs
Tan livrezon Surge Stop:
3-15 jou apre konfime lòd la, dat livrezon detay yo ta dwe deside selon sezon pwodiksyon ak kantite lòd.
Livrezon Surge Arrester:
1. chajman pò:SHANGHAI/NINGBO
2. Pa lè oswa pa lanmè pou machandiz pakèt, ayewopò / pò k ap resevwa;
3. Kliyan ki espesifye transpòtè machandiz oswa metòd anbake negosyab!
Enfòmasyon sou konpayi



Baj popilè: nouvo konsepsyon aparèy pwoteksyon vag 2p 600 800vdc, Lachin, manifaktirè, founisè, faktori, pri
Ou ka renmen tou
Voye rechèch